![]() |
MOQ: | 100個のPC |
価格: | 2,000 - 5,000 USD per pc |
標準パッケージ: | 鉄フレームとの輸出のための海の価値があるパッキング |
配達期間: | 頭金かL/Cを得た後90日以内に |
決済方法: | T/T、一覧でL/C |
供給能力: | 1ヶ月あたりの約1,000トン |
Attribute | Value |
---|---|
Type | Natural Circulation |
Application | boiler maintaince, Boiler Pipe, Heating element |
Material | Stainless steel |
Usage | Industrial, Power Station, Thermal power plant/station boiler |
Color | Customized |
Fuel | Biomass, Waste |
Inspection | ASME Inspection |
Style | Horizontal and Vertical |
Superheater handles saturated steam; reheater processes partially expanded steam.
Use for heating saturated steam, steam temperature could be up to 900 degree C.
Superheater Capacity Upgrades to Increase Power Generation
Send us required technical data, such as steam capacity, pressure, required temperature etc. We will design accordingly.
Type | Advantages | Disadvantages | Supporting method |
---|---|---|---|
Pendant-type | 1. Firm structural support | 1. Flow blockage by condensed steam 2. Needs a slow restart to purge the water that accumulates in the bottom. |
supported from above |
Inverted-type | 1. Proper drainage of the condensed steam | 1. Lack the structural rigidity, especially in high speed gas flow | Supported from below |
Horizontal-type | 1. Proper drainage 2. Good structural rigidity. |
1. They do not view the flame directly so they are mainly from the convective type | Usually supported in the vertical gas ducts parallel to the main furnace. |
![]() |
MOQ: | 100個のPC |
価格: | 2,000 - 5,000 USD per pc |
標準パッケージ: | 鉄フレームとの輸出のための海の価値があるパッキング |
配達期間: | 頭金かL/Cを得た後90日以内に |
決済方法: | T/T、一覧でL/C |
供給能力: | 1ヶ月あたりの約1,000トン |
Attribute | Value |
---|---|
Type | Natural Circulation |
Application | boiler maintaince, Boiler Pipe, Heating element |
Material | Stainless steel |
Usage | Industrial, Power Station, Thermal power plant/station boiler |
Color | Customized |
Fuel | Biomass, Waste |
Inspection | ASME Inspection |
Style | Horizontal and Vertical |
Superheater handles saturated steam; reheater processes partially expanded steam.
Use for heating saturated steam, steam temperature could be up to 900 degree C.
Superheater Capacity Upgrades to Increase Power Generation
Send us required technical data, such as steam capacity, pressure, required temperature etc. We will design accordingly.
Type | Advantages | Disadvantages | Supporting method |
---|---|---|---|
Pendant-type | 1. Firm structural support | 1. Flow blockage by condensed steam 2. Needs a slow restart to purge the water that accumulates in the bottom. |
supported from above |
Inverted-type | 1. Proper drainage of the condensed steam | 1. Lack the structural rigidity, especially in high speed gas flow | Supported from below |
Horizontal-type | 1. Proper drainage 2. Good structural rigidity. |
1. They do not view the flame directly so they are mainly from the convective type | Usually supported in the vertical gas ducts parallel to the main furnace. |